故障排除

在这里,你会发现一个常见的问题集合。

在恢复壳中开始

如果你的操作系统不能如下图所示启动,请执行以下步骤。

+++ Found verified kexec boot params
gpg: verify signatures failed: Unknown system error
Invalid signature on kexec boot params
!!!!! Failed default boot
New value of PCR[4]: XXXXXXXXXXXXXXXXXXXXXXXXXXXXX
!!!!!Starting recovery shell
/boot #
  1. 重新启动你的笔记本电脑并进入选项。

    img1
  2. 选择 "更新校验和并签署/boot上的所有文件"。

    img2
  3. 之后,请按照`这些说明<system-update.html>`_从第3步开始。

NitroPad无法启动

If the laptop does not start and only flashes briefly when switched on, please try the following steps:

  1. 尝试硬重启。卸下电源和电池,按住电源按钮20秒。然后重新连接电源和电池并启动。

  2. 如果这不起作用取出电池或仅在连接电源的情况下启动。

  3. 你也可以尝试拆下RAM,然后重新插入。

无效代码

Each boot the code is generated on the NitroPad and the Nitrokey, if its connected. It is allowed to run 10 boots without loosing the synchronization between the devices, after which the bad code signal is shown, regardless of the rest of the system being in a correct state. If you are sure the system was not beign tampered with (e.g. the NitroPad was booted more than 10 times without the Nitrokey), you can safely reset the system’s warning.

请连接Nitrokey并在主启动屏幕上执行以下内容。

  1. 选择

  2. TPM/TOTP/HOTP选项

  3. 生成新的TOTP/HOTP秘密

并按照屏幕上的提示操作。之后,秘密和计数器应该都被重置为一个新的值。